Electrical Specifications
This page outlines the electrical specs and safe operating parameters for the OV20i camera, including power requirements, I/O behavior, pin assignments, and current limits.
Power Requirements
- Input Voltage: 19–24 VDC regulated power supply
- Typical Current Draw: 600–800 mA
- Startup Inrush Current: ~1.5 A (brief)
- Recommended Power Supply: 24 VDC, 2 A (minimum)
Power Connector:
- M12 A-coded, 17-pin male connector
- Only pins 5, 6 (GND) and 13, 14 (VIN) are used for power
Digital I/O Specs
The OV20i supports 5 digital I/O lines through the power I/O connector:
Type | Lines | Logic | Current Rating |
---|---|---|---|
Inputs | 3 | NPN-compatible (sinking logic) | – |
Outputs | 2 | NPN open collector | 100 mA max per line |
Trigger Input | 1 | Pull to GND to activate | – |
- Output Protection: Overcurrent protection with internal thermal fuse
- DIO GND: Must be tied to PLC/system ground for reliable input detection
I/O Connector Pinout (M12 A-Coded, 17-pin)
Pin | Signal | Function |
---|---|---|
5–6 | Power GND | 0V return |
7 | DIO GND | Digital I/O return path |
8 | Digital Input 0 | Sensor or PLC input (NPN) |
9 | Digital Input 1 | Sensor or PLC input (NPN) |
10 | Digital Output 0 | NPN open collector output |
11 | Digital Output 1 | NPN open collector output |
12 | RS232 RX | Optional (not commonly used) |
13–14 | Power VIN | +24 VDC supply input |
15 | Reset Input | Pull low to reboot (only if instructed) |
16 | Trigger Input | Main hardware trigger input (NPN/dry) |
Others | Reserved / Not Used | No connection |
Communication Ports
Port | Type | Use |
---|---|---|
RJ45 | M12 X-Coded Ethernet | Gigabit network comms |
Micro USB | USB 2.0 | Emergency IP recovery |
- Micro USB IP: 192.168.55.1 (auto when connected to a PC)
- Main Camera IP (default): 192.168.0.100
Electrical Design Notes
- Use NPN-compatible sensors/relays when possible.
- Pull to GND to activate inputs.
- Outputs require external 24 V to drive loads.
- Do not exceed 100 mA per output line.
- Always connect DIO GND to external system GND for reliable operation.
Protection & Safety
- Built-in thermal fuse protects DIO GND return
- Ensure proper grounding to prevent floating inputs or noise
- Outputs are floating unless active (NPN open collector)