Skip to main content

Electrical Specifications

This page outlines the electrical specs and safe operating parameters for the OV20i camera, including power requirements, I/O behavior, pin assignments, and current limits.

Power Requirements

  • Input Voltage: 19–24 VDC regulated power supply
  • Typical Current Draw: 600–800 mA
  • Startup Inrush Current: ~1.5 A (brief)
  • Recommended Power Supply: 24 VDC, 2 A (minimum)

Power Connector:

  • M12 A-coded, 17-pin male connector
  • Only pins 5, 6 (GND) and 13, 14 (VIN) are used for power

Digital I/O Specs

The OV20i supports 5 digital I/O lines through the power I/O connector:

TypeLinesLogicCurrent Rating
Inputs3NPN-compatible (sinking logic)
Outputs2NPN open collector100 mA max per line
Trigger Input1Pull to GND to activate
  • Output Protection: Overcurrent protection with internal thermal fuse
  • DIO GND: Must be tied to PLC/system ground for reliable input detection

I/O Connector Pinout (M12 A-Coded, 17-pin)

image.png

PinSignalFunction
5–6Power GND0V return
7DIO GNDDigital I/O return path
8Digital Input 0Sensor or PLC input (NPN)
9Digital Input 1Sensor or PLC input (NPN)
10Digital Output 0NPN open collector output
11Digital Output 1NPN open collector output
12RS232 RXOptional (not commonly used)
13–14Power VIN+24 VDC supply input
15Reset InputPull low to reboot (only if instructed)
16Trigger InputMain hardware trigger input (NPN/dry)
OthersReserved / Not UsedNo connection

Communication Ports

PortTypeUse
RJ45M12 X-Coded EthernetGigabit network comms
Micro USBUSB 2.0Emergency IP recovery
  • Micro USB IP: 192.168.55.1 (auto when connected to a PC)
  • Main Camera IP (default): 192.168.0.100

Electrical Design Notes

  • Use NPN-compatible sensors/relays when possible.
  • Pull to GND to activate inputs.
  • Outputs require external 24 V to drive loads.
  • Do not exceed 100 mA per output line.
  • Always connect DIO GND to external system GND for reliable operation.

Protection & Safety

  • Built-in thermal fuse protects DIO GND return
  • Ensure proper grounding to prevent floating inputs or noise
  • Outputs are floating unless active (NPN open collector)